Amercor™ CF6721 Corrosion Inhibitor
GoalResolve a copper corrosion issue at a pulp mill.
50%
Reduced copper in boiler feedwater
⬆
Improved corrosion protection, feed and stability
✪
Extended pulp dryer coil life
GoalResolve a copper corrosion issue at a pulp mill.
<h6>Improvement Opportunity</h6> <p>A pulp mill in the Southeast United States was experiencing unacceptable copper corrosion from a pulp dryer, as evidenced by copper in the condensate and boiler feedwater. The previous condensate treatment to the pulp dryer proved to be difficult to feed and the resulting inconsistent treatment resulted in higher than desired copper in the condensate, especially during start-up from outages.</p> <h6>Recommended Solution</h6> <p>Solenis’ Amercor CF6721, which utilizes new filming technology combined with ease of feed, replaced the previous treatment. Feed reliability is exceptional and is due to the low viscosity and stability of the product. A proprietary analytical test, which is not available for most other types of filming amines, is used to verify product feed.</p> <h6>Results Achieved</h6> <p>After initiating feed, the iron and copper temporarily increased as expected due to the superior ability of the amine to tightly adhere to heat exchange surfaces. This loosens existing metal oxides and assists in forming a new and denser protective oxide layer. After a short time, the copper levels were reduced to half of what had been previously achieved. Feed of the Amercor CF6721 resulted in iron and copper levels in condensate well below industry standards.</p> <p><img style="max-width: 100%; width: auto; height: auto; display: block; margin-left: auto; margin-right: auto;" src="/link/693888be6aec45099122ab4da55f1bf9.aspx" alt="" width="800" height="455" /></p>
50%
Reduced copper in boiler feedwater
⬆
Improved corrosion protection, feed and stability
✪
Extended pulp dryer coil life