Amerfloc™ 412 Coagulant and Praestol™ 2234-EU Flocculant
GoalImprove performance of DAF unit and downstream systems.
$500k
Saving yearly in water costs
600k
m3/yr water savings
☑
Water quality standards achieved
GoalImprove performance of DAF unit and downstream systems.
<h6>Customer Challenge</h6> <p>A 550 m<sup>3</sup>/h wastewater treatment plant in a large refinery in Western Europe was experiencing challenges due to high hydrocarbon load in the raw wastewater. The treatment process included a DAF (Dissolved Air Flotation) unit for solid-liquid separation followed by secondary biological treatment and tertiary sand filters to allow partial water recycling as cooling make-up. High organics in the raw wastewater were negatively impacting the performance of the DAF and downstream biological treatment. Consequently, the plant could not always achieve the discharge limits and therefore only a small amount of wastewater could be recycled as cooling water make-up by blending with large volumes of fresh water.</p> <h6>Recommended Solution</h6> <p>An extensive survey and lab trial was performed by Solenis to improve the DAF performance and downstream systems. The selected chemical program was based on Amerfloc 412 coagulant combined with Praestol 2234-EU flocculant.</p> <h6>Results Achieved</h6> <p>The dual program achieved the following:</p> <ul style="text-align: center;"> <li style="text-align: left;">Outstanding removal of hydrocarbons from the water</li> <li style="text-align: left;">Enhanced clarification performance of the DAF unit</li> <li style="text-align: left;">Low turbidity of DAF outlet</li> <li style="text-align: left;">Discharge limits were controlled and kept within limits</li> <li style="text-align: left;">Increased wastewater recycling to cooling from 30 m<sup>3</sup>/h to 100 m<sup>3</sup>/h</li> </ul> <table style="height: 169.766px; border-collapse: collapse; width: 592px; margin-left: auto; margin-right: auto;" border="1" width="397"> <tbody> <tr style="height: 37.168px;"> <td style="height: 37.168px; width: 577.774px;" colspan="4"> <p style="text-align: center;"><strong>Ranking 0 = bad; 5 = excellent</strong></p> </td> </tr> <tr style="height: 58.2422px;"> <td style="height: 58.2422px; width: 153.809px; text-align: center;"> <p><strong>Coagulant</strong></p> </td> <td style="height: 58.2422px; width: 166.133px; text-align: center;"> <p><strong>Lab dosage (ppm)</strong></p> </td> <td style="height: 58.2422px; width: 128.809px; text-align: center;"> <p><strong>Floc quality</strong></p> </td> <td style="height: 58.2422px; width: 129.023px; text-align: center;"> <p><strong>Water quality</strong></p> </td> </tr> <tr style="height: 37.168px;"> <td style="height: 37.168px; width: 153.809px; text-align: center;"> <p><strong>Amerfloc 412</strong></p> </td> <td style="height: 37.168px; width: 166.133px; text-align: center;"> <p>100</p> </td> <td style="height: 37.168px; width: 128.809px; text-align: center;"> <p>4</p> </td> <td style="height: 37.168px; width: 129.023px; text-align: center;"> <p>4</p> </td> </tr> <tr style="height: 37.1875px;"> <td style="height: 37.1875px; width: 153.809px; text-align: center;"> <p><strong>Incumbent</strong></p> </td> <td style="height: 37.1875px; width: 166.133px; text-align: center;"> <p>100</p> </td> <td style="height: 37.1875px; width: 128.809px; text-align: center;"> <p>2</p> </td> <td style="height: 37.1875px; width: 129.023px; text-align: center;"> <p>2</p> </td> </tr> </tbody> </table> <p style="text-align: center;">Laboratory Coagulant Selection Performance Test Result</p>
$500k
Saving yearly in water costs
600k
m3/yr water savings
☑
Water quality standards achieved